A Data-Driven Passive Islanding Detection Scheme
This paper proposes a novel statistical parameters based data driven approach for passive islanding detection. The proposed scheme relies in the voltage data, measured at the point of common coupling, and is comprised of three stages. The Stage-1 quickly detects what is termed as coarse islanding, Stage-2 computes the decaying DC detector (DDCD), and 3) finally, the digital relay logic (DRL) is devised in Stage-3. The proposed scheme is tested as per the IEEE-1547, UL 1741 and IEC-62116 standards. Various tests are investigated on the modified IEEE-13 bus system, modeled in PSCAD/EMTDC, under stringent test scenarios such as power mismatch, induction motor starting effect, capacitor bank switching and various level of loads changes, considered for both single and multiple DG systems. The test results reveal that the proposed scheme can detect islanding in less than 2 cycles, and results in nearly zero non detection zone (NDZ). Also, the scheme can very well be used for single-phase microgrids too as it relies only on the single phase voltage information.
Citation Formats
TY - DATA
AB - This paper proposes a novel statistical parameters based data driven approach for passive islanding detection. The proposed scheme relies in the voltage data, measured at the point of common coupling, and is comprised of three stages. The Stage-1 quickly detects what is termed as coarse islanding, Stage-2 computes the decaying DC detector (DDCD), and 3) finally, the digital relay logic (DRL) is devised in Stage-3. The proposed scheme is tested as per the IEEE-1547, UL 1741 and IEC-62116 standards. Various tests are investigated on the modified IEEE-13 bus system, modeled in PSCAD/EMTDC, under stringent test scenarios such as power mismatch, induction motor starting effect, capacitor bank switching and various level of loads changes, considered for both single and multiple DG systems. The test results reveal that the proposed scheme can detect islanding in less than 2 cycles, and results in nearly zero non detection zone (NDZ). Also, the scheme can very well be used for single-phase microgrids too as it relies only on the single phase voltage information.
AU - Reddy, M. Venkateswara
A2 - De, Sourav
A3 - Sodhi, Ranjana
DB - C-MIX - Community Microgrid Information Exchange
DP - Open EI | National Laboratory of the Rockies
DO - 10.1109/PIICON56320.2022.10045174
KW - Power electronics and inverters
KW - Power electronics
KW - Inverters
KW - Battery energy storage
KW - Solar
KW - Photovoltaics
KW - PV
KW - Diesel generators
KW - Other liquid-fuel generators
KW - Standards
KW - Interconnection
KW - Protection
KW - Case studies
KW - Performance
LA - English
DA - 2023/01/01
PY - 2023
PB - NLR
T1 - A Data-Driven Passive Islanding Detection Scheme
UR - https://doi.org/10.1109/PIICON56320.2022.10045174
ER -
Reddy, M. Venkateswara, et al. A Data-Driven Passive Islanding Detection Scheme. NLR, 1 January, 2023, C-MIX - Community Microgrid Information Exchange. https://doi.org/10.1109/PIICON56320.2022.10045174.
Reddy, M., De, S., & Sodhi, R. (2023). A Data-Driven Passive Islanding Detection Scheme. [Data set]. C-MIX - Community Microgrid Information Exchange. NLR. https://doi.org/10.1109/PIICON56320.2022.10045174
Reddy, M. Venkateswara, Sourav De, and Ranjana Sodhi. A Data-Driven Passive Islanding Detection Scheme. NLR, January, 1, 2023. Distributed by C-MIX - Community Microgrid Information Exchange. https://doi.org/10.1109/PIICON56320.2022.10045174
@misc{CMIX_Dataset_78,
title = {A Data-Driven Passive Islanding Detection Scheme},
author = {Reddy, M. Venkateswara and De, Sourav and Sodhi, Ranjana},
abstractNote = {This paper proposes a novel statistical parameters based data driven approach for passive islanding detection. The proposed scheme relies in the voltage data, measured at the point of common coupling, and is comprised of three stages. The Stage-1 quickly detects what is termed as coarse islanding, Stage-2 computes the decaying DC detector (DDCD), and 3) finally, the digital relay logic (DRL) is devised in Stage-3. The proposed scheme is tested as per the IEEE-1547, UL 1741 and IEC-62116 standards. Various tests are investigated on the modified IEEE-13 bus system, modeled in PSCAD/EMTDC, under stringent test scenarios such as power mismatch, induction motor starting effect, capacitor bank switching and various level of loads changes, considered for both single and multiple DG systems. The test results reveal that the proposed scheme can detect islanding in less than 2 cycles, and results in nearly zero non detection zone (NDZ). Also, the scheme can very well be used for single-phase microgrids too as it relies only on the single phase voltage information.},
url = {https://cmix.openei.org/submissions/78},
year = {2023},
howpublished = {C-MIX - Community Microgrid Information Exchange, NLR, https://doi.org/10.1109/PIICON56320.2022.10045174},
note = {Accessed: 2026-11-28},
doi = {10.1109/PIICON56320.2022.10045174}
}
https://dx.doi.org/10.1109/PIICON56320.2022.10045174
Details
Data from Jan 1, 2023
Last updated Mar 30, 2026
Submitted Jun 2, 2026
Organization
NLR
Contact
Venkateswara Motakatla