Improved Control Strategy of Grid-Forming Inverters for Fault Ride-Through in a Microgrid System
This paper develops an improved control strategy of grid-forming (GFM) inverters with fault ride-through capabilities to guarantee the stable operation of microgrids under fault conditions, especially islanded microgrids and asymmetrical faults. The proposed control strategy includes the dual control of positive-sequence and negative-sequence control as well as the adaptive virtual impedance (VI) control. Unlike existing works, the proposed strategy applies the VI control for only the d component of the positive-sequence control and leaves the q component of the positive-sequence control and the dq component of the negative-sequence control as zero, thus achieving improved stability and balanced three-phase voltages under asymmetrical faults. The adaptive feature of the VI control guarantees the stability of the GFM inverter under severe faults, which could cause the saturation of the inner current loop and instability if the VI is not adaptive. Simulation results of various unbalanced faults with high- and low-fault impedances show that the proposed control strategy improves the stability of the GFM inverter and achieves stable and balanced output voltages in islanded microgrids. And the algorithm also improves the stability of GFM inverters under balanced faults with high- and low-fault impedances.
Citation Formats
TY - DATA
AB - This paper develops an improved control strategy of grid-forming (GFM) inverters with fault ride-through capabilities to guarantee the stable operation of microgrids under fault conditions, especially islanded microgrids and asymmetrical faults. The proposed control strategy includes the dual control of positive-sequence and negative-sequence control as well as the adaptive virtual impedance (VI) control. Unlike existing works, the proposed strategy applies the VI control for only the d component of the positive-sequence control and leaves the q component of the positive-sequence control and the dq component of the negative-sequence control as zero, thus achieving improved stability and balanced three-phase voltages under asymmetrical faults. The adaptive feature of the VI control guarantees the stability of the GFM inverter under severe faults, which could cause the saturation of the inner current loop and instability if the VI is not adaptive. Simulation results of various unbalanced faults with high- and low-fault impedances show that the proposed control strategy improves the stability of the GFM inverter and achieves stable and balanced output voltages in islanded microgrids. And the algorithm also improves the stability of GFM inverters under balanced faults with high- and low-fault impedances.
AU - Wang, Jing
DB - C-MIX - Community Microgrid Information Exchange
DP - Open EI | National Laboratory of the Rockies
DO - 10.1109/ECCE50734.2022.9948153
KW - Hydropower
KW - Marine energy
KW - Marine hydrokinetic
KW - Ocean energy
KW - Power electronics and inverters
KW - Power electronics
KW - Inverters
KW - Battery energy storage
KW - Solar
KW - Photovoltaics
KW - PV
KW - Power plant controls
KW - SCADA
KW - Standards
KW - Interconnection
KW - Protection
KW - Case studies
KW - Performance
LA - English
DA - 2022/01/01
PY - 2022
PB - NLR
T1 - Improved Control Strategy of Grid-Forming Inverters for Fault Ride-Through in a Microgrid System
UR - https://doi.org/10.1109/ECCE50734.2022.9948153
ER -
Wang, Jing. Improved Control Strategy of Grid-Forming Inverters for Fault Ride-Through in a Microgrid System. NLR, 1 January, 2022, C-MIX - Community Microgrid Information Exchange. https://doi.org/10.1109/ECCE50734.2022.9948153.
Wang, J. (2022). Improved Control Strategy of Grid-Forming Inverters for Fault Ride-Through in a Microgrid System. [Data set]. C-MIX - Community Microgrid Information Exchange. NLR. https://doi.org/10.1109/ECCE50734.2022.9948153
Wang, Jing. Improved Control Strategy of Grid-Forming Inverters for Fault Ride-Through in a Microgrid System. NLR, January, 1, 2022. Distributed by C-MIX - Community Microgrid Information Exchange. https://doi.org/10.1109/ECCE50734.2022.9948153
@misc{CMIX_Dataset_22,
title = {Improved Control Strategy of Grid-Forming Inverters for Fault Ride-Through in a Microgrid System},
author = { Wang, Jing},
abstractNote = {This paper develops an improved control strategy of grid-forming (GFM) inverters with fault ride-through capabilities to guarantee the stable operation of microgrids under fault conditions, especially islanded microgrids and asymmetrical faults. The proposed control strategy includes the dual control of positive-sequence and negative-sequence control as well as the adaptive virtual impedance (VI) control. Unlike existing works, the proposed strategy applies the VI control for only the d component of the positive-sequence control and leaves the q component of the positive-sequence control and the dq component of the negative-sequence control as zero, thus achieving improved stability and balanced three-phase voltages under asymmetrical faults. The adaptive feature of the VI control guarantees the stability of the GFM inverter under severe faults, which could cause the saturation of the inner current loop and instability if the VI is not adaptive. Simulation results of various unbalanced faults with high- and low-fault impedances show that the proposed control strategy improves the stability of the GFM inverter and achieves stable and balanced output voltages in islanded microgrids. And the algorithm also improves the stability of GFM inverters under balanced faults with high- and low-fault impedances.},
url = {https://cmix.openei.org/submissions/22},
year = {2022},
howpublished = {C-MIX - Community Microgrid Information Exchange, NLR, https://doi.org/10.1109/ECCE50734.2022.9948153},
note = {Accessed: 2026-10-11},
doi = {10.1109/ECCE50734.2022.9948153}
}
https://dx.doi.org/10.1109/ECCE50734.2022.9948153
Details
Data from Jan 1, 2022
Last updated Mar 30, 2026
Submitted Jun 2, 2026
Organization
NLR
Contact
Jing Wang