Thermal energy storage (TES) and distributed generation technologies, such as combined heat and power (CHP) or photovoltaics (PV), can be used to reduce energy costs and decrease CO2 emissions from buildings by shifting energy consumption to times with less emissions and/or lower energy prices. To determine the feasibility of investing in TES in combination with other distributed energy resources (DER), mixed integer linear programming (MILP) can be used. Such a MILP model is the well-established Distributed Energy Resources Customer Adoption Model (DER-CAM); however, it currently uses only a simplified TES model to guarantee linearity and short run-times. Loss calculations are based only on the energy contained in the storage. This paper presents a new DER-CAM TES model that allows improved tracking of losses based on ambient and storage temperatures, and compares results with the previous version. A multi-layer TES model is introduced that retains linearity and avoids creating an endogenous optimization problem. The improved model increases the accuracy of the estimated storage losses and enables use of heat pumps for low temperature storage charging. Results indicate that the previous model overestimates the attractiveness of TES investments for cases without possibility to invest in heat pumps and underestimates it for some locations when heat pumps are allowed. Despite a variation in optimal technology selection between the two models, the objective function value stays quite stable, illustrating the complexity of optimal DER sizing problems in buildings and microgrids.

Citation Formats

TY - DATA AB - Thermal energy storage (TES) and distributed generation technologies, such as combined heat and power (CHP) or photovoltaics (PV), can be used to reduce energy costs and decrease CO2 emissions from buildings by shifting energy consumption to times with less emissions and/or lower energy prices. To determine the feasibility of investing in TES in combination with other distributed energy resources (DER), mixed integer linear programming (MILP) can be used. Such a MILP model is the well-established Distributed Energy Resources Customer Adoption Model (DER-CAM); however, it currently uses only a simplified TES model to guarantee linearity and short run-times. Loss calculations are based only on the energy contained in the storage. This paper presents a new DER-CAM TES model that allows improved tracking of losses based on ambient and storage temperatures, and compares results with the previous version. A multi-layer TES model is introduced that retains linearity and avoids creating an endogenous optimization problem. The improved model increases the accuracy of the estimated storage losses and enables use of heat pumps for low temperature storage charging. Results indicate that the previous model overestimates the attractiveness of TES investments for cases without possibility to invest in heat pumps and underestimates it for some locations when heat pumps are allowed. Despite a variation in optimal technology selection between the two models, the objective function value stays quite stable, illustrating the complexity of optimal DER sizing problems in buildings and microgrids. AU - Steen, David A2 - Stadler, Michael A3 - Cardoso, Gonçalo A4 - Groissböck, Markus A5 - DeForest, Nicholas A6 - Marnay, Chris DB - C-MIX - Community Microgrid Information Exchange DP - Open EI | National Laboratory of the Rockies DO - 10.1016/j.apenergy.2014.07.036 KW - Combined heat and power (CHP) KW - Thermal energy systems KW - TENs KW - District energy KW - Fuel cells KW - Financing KW - Business models KW - Case studies KW - Performance KW - Planning and design KW - Planning KW - Design LA - English DA - 2015/01/01 PY - 2015 PB - Lawrence Berkeley National Laboratory T1 - Modeling of Thermal Storage Systems in MILP Distributed Energy Resource Models UR - https://doi.org/10.1016/j.apenergy.2014.07.036 ER -
Export Citation to RIS
Steen, David, et al. Modeling of Thermal Storage Systems in MILP Distributed Energy Resource Models. Lawrence Berkeley National Laboratory, 1 January, 2015, C-MIX - Community Microgrid Information Exchange. https://doi.org/10.1016/j.apenergy.2014.07.036.
Steen, D., Stadler, M., Cardoso, G., Groissböck, M., DeForest, N., & Marnay, C. (2015). Modeling of Thermal Storage Systems in MILP Distributed Energy Resource Models. [Data set]. C-MIX - Community Microgrid Information Exchange. Lawrence Berkeley National Laboratory. https://doi.org/10.1016/j.apenergy.2014.07.036
Steen, David, Michael Stadler, Gonçalo Cardoso, Markus Groissböck, Nicholas DeForest, and Chris Marnay. Modeling of Thermal Storage Systems in MILP Distributed Energy Resource Models. Lawrence Berkeley National Laboratory, January, 1, 2015. Distributed by C-MIX - Community Microgrid Information Exchange. https://doi.org/10.1016/j.apenergy.2014.07.036
@misc{CMIX_Dataset_232, title = {Modeling of Thermal Storage Systems in MILP Distributed Energy Resource Models}, author = {Steen, David and Stadler, Michael and Cardoso, Gonçalo and Groissb\"{o}ck, Markus and DeForest, Nicholas and Marnay, Chris}, abstractNote = {Thermal energy storage (TES) and distributed generation technologies, such as combined heat and power (CHP) or photovoltaics (PV), can be used to reduce energy costs and decrease CO2 emissions from buildings by shifting energy consumption to times with less emissions and/or lower energy prices. To determine the feasibility of investing in TES in combination with other distributed energy resources (DER), mixed integer linear programming (MILP) can be used. Such a MILP model is the well-established Distributed Energy Resources Customer Adoption Model (DER-CAM); however, it currently uses only a simplified TES model to guarantee linearity and short run-times. Loss calculations are based only on the energy contained in the storage. This paper presents a new DER-CAM TES model that allows improved tracking of losses based on ambient and storage temperatures, and compares results with the previous version. A multi-layer TES model is introduced that retains linearity and avoids creating an endogenous optimization problem. The improved model increases the accuracy of the estimated storage losses and enables use of heat pumps for low temperature storage charging. Results indicate that the previous model overestimates the attractiveness of TES investments for cases without possibility to invest in heat pumps and underestimates it for some locations when heat pumps are allowed. Despite a variation in optimal technology selection between the two models, the objective function value stays quite stable, illustrating the complexity of optimal DER sizing problems in buildings and microgrids.}, url = {https://cmix.openei.org/submissions/232}, year = {2015}, howpublished = {C-MIX - Community Microgrid Information Exchange, Lawrence Berkeley National Laboratory, https://doi.org/10.1016/j.apenergy.2014.07.036}, note = {Accessed: 2026-10-11}, doi = {10.1016/j.apenergy.2014.07.036} }
https://dx.doi.org/10.1016/j.apenergy.2014.07.036

Details

Data from Jan 1, 2015

Last updated Mar 30, 2026

Submitted Jun 2, 2026

Organization

Lawrence Berkeley National Laboratory

Contact

David Steen

Authors

David Steen

Lawrence Berkeley National Laboratory

Michael Stadler

Lawrence Berkeley National Laboratory

Gonçalo Cardoso

Lawrence Berkeley National Laboratory

Markus Groissböck

Lawrence Berkeley National Laboratory

Nicholas DeForest

Lawrence Berkeley National Laboratory

Chris Marnay

Lawrence Berkeley National Laboratory
Submission Downloads